Muton Rockhopper 46 Guia do Utilizador Página 129

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 128
Rockhopper II series printers – User’s Guide
129
AP-75095, Rev. 2.1, 18/08/2005
5.5.2. Controlling the heater elements on the Rockhopper II 4H printer
If you want to change or check the heater elements, follow the steps below.
Step 1 :
Press the [F1] key on the operation panel.
¾ The printer works as follows.
Ready to Print
F1
Heaters Cleaning
F2
F3
Cut&Feed LeverUp
F4
User1 xxxm
By pressing the [F1] key, you will have direct access to control or change the heaters
temperatures.
After pressing the [F1] key in the normal status, the operation panel will mention the following :
* Heaters * (1/2)
F1
A : S 50 – R 50 B : S 50 – R 50
F2
F3
C : S 50 – R 50 D : S 50 – R 50
F4
heater message
* Heaters * (2/2)
F1
SET ON
heater message
The ‘heater message’ can be one of the following:
Heater standby
Heater warming up
Heater ready
Notes :
Previous firmware mention : ‘Heater standby’, ‘Heater ON’, ‘Heater OFF’, ‘Heater ON
(A)’, ‘Heater ON (D)’, ‘Heater ON (B)’, ‘Heater ON (C)’, ‘Heater ON (A, B)’, ‘Heater ON
(A, C)’, ‘Heater ON (A, D)’, ‘Heater ON (A, B, C)’, ‘Heater ON (A, B, D)’, ‘Heater ON (A,
C, D)’, ‘Heater ON (B, C)’, ‘Heater ON (B, D)’ and ‘Heater ON (C, D)’
‘A’ stands for the heater.
‘B’ stands for the fixer.
‘C’ stands for the post fixer.
‘D’ stands for the dryer.
‘S’ stands for the Set-temperature (requested temperature).
‘R’ stands for the Real-temperature (actual temperature).